Engineered for Continuous Flow
Aytok semi-automatic filters are built to ensure your operations never stop, delivering an uninterrupted supply of clean water even during cleaning cycles.
Their smart design uses a pressure differential system to alert the user when a manual cleaning cycle is needed.
This simple user-activated flush efficiently purges all contaminants without halting filtration, guaranteeing trouble-free performance and delivering constant reliability when it matters most.
GENERAL SPECIFICATION
▪️Body Material : PA6GFR30
▪️Cartridge Material : SS304L, PA6GFR30
▪️Maximum Working Pressure : 8bar ; 116 Psi
▪️Minimum Working Pressure : 1 bar ; 14.5 Psi
▪️Maximum Working Temperature : 60°C ; 140°F
▪️Control System : Semi Automatic Control
▪️Filtration Sensitivity : 20-2000 µ (micron)
CLEANING PROCESS
The manual flushing process is initiated by opening the filter's flush valve and rotating the cleaning handle at a constant speed. This rotation moves a set of internal nozzles across the screen surface. The open valve creates a localized pressure drop, generating a high-velocity suction effect through the nozzles that vacuums contaminants off the screen and discharges them. The cleaning cycle consists of two passes: a primary pass as the handle is turned to its limit, and a secondary pass as it is rotated back to its home position. The process is completed by closing the flush valve.
WORKING PRINCIPLE
Water enters the filter and passes through the fine screen element. filtration element.During operation, contaminants gradually accumulate on the inner surface for screens. This buildup obstructs the water flow, creating a pressure differential between the filter's inlet and outlet. Manual cleaning is required when this pressure differential reaches 0.7 bar.
No customer reviews for the moment.

Engineered for Continuous Flow
Aytok semi-automatic filters are built to ensure your operations never stop, delivering an uninterrupted supply of clean water even during cleaning cycles.
Their smart design uses a pressure differential system to alert the user when a manual cleaning cycle is needed.
This simple user-activated flush efficiently purges all contaminants without halting filtration, guaranteeing trouble-free performance and delivering constant reliability when it matters most.
check_circle
check_circle